Nextel comm Modem IR1200 User Manual

Browse online or download User Manual for Networking Nextel comm Modem IR1200. Nextel comm Modem IR1200 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 122
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - Administrator’s Guide

 iR1200 Rugged Modem iR1200 GPS-Enabled Modem Administrator’s Guide General

Page 3 - Table of Contents

iR1200 Modem 90 nextel.com Register # Function 8 Command Dial Modifier Time. Valid value ranges from 0 (zero) to 255 seconds. 2 (seconds) is th

Page 4 - 

Troubleshooting RFM-4002-5015 Rev 3 91 Troubleshooting This chapter describes typical configuration problems and provides instructions on how to tr

Page 5

iR1200 Modem 92 nextel.com Symptom Troubleshooting Tips modem. • The cable is connected to the correct port. • The correct port is specified i

Page 6

Troubleshooting RFM-4002-5015 Rev 3 93 Symptom Troubleshooting Tips Modem keeps dropping connection. Check the signal strength and signal quality

Page 7

iR1200 Modem 94 nextel.com Message Explanation • An invalid parameter was entered. The command line is ready for another command. Make sure tha

Page 8

Troubleshooting RFM-4002-5015 Rev 3 95 any ongoing data connections. 3 Establish basic computer to modem communication. 4 Administer the followin

Page 9 - IMPORTANT!

iR1200 Modem 96 nextel.com Code General Description 268 Invalid DTE-IP address was specified (+WPNEI). 269 Invalid Home Agent address was specif

Page 10

Troubleshooting RFM-4002-5015 Rev 3 97 Code General Description 1027 SLIP/PPP link terminated. Circuit Data Operation 1280 No information is avail

Page 11 - Table of Figures

iR1200 Modem 98 nextel.com Code General Description 1594 Bearer capability is not presently available. 1593 Bearer capability is not authorized.

Page 12 - 2 nextel.com

Safety Notice RFM-4000-5015 Rev1 99 Safety Notice The following information is important for the safe and efficient operation of the iR1200 modem.

Page 13 - FCC Compliance

Table of Figures RFM-4002-5015 Rev 3 1 Table of Figures Table of Figures Page Figure 1 – iR1200 GPS-Enabled Modem 9 Figure 2 – Rear Panel of iR12

Page 14 - 4 nextel.com

iR1200 Modem 100 nextel.com Hearing Aids The modem may interfere with hearing aid devices. Individuals who experience such interference should consu

Page 15 - Required Components

Copyright and Trademark RFM-4000-5015 Rev1 101 Copyright and Trademark © 2003 Nextel Communications, Inc. Nextel and the Nextel logo are service ma

Page 16 - Online Documentation

iR1200 Modem 102 nextel.com

Page 17 - Introduction

Appendix A: Glossary RFM-4000-5015 Rev1 103 Appendix A: Glossary This glossary contains terms and definitions used within this guide. It is by no m

Page 18 - Customer Care

iR1200 Modem 104 nextel.com through. Circuit Switch was originally developed for the analog-based telephone system in order to guarantee steady, con

Page 19 - Overview

Appendix A: Glossary RFM-4000-5015 Rev1 105 Differential GPS A procedure of correcting GPS solutions to achieve improved position accuracy. Differe

Page 20 - Modem Configurations

iR1200 Modem 106 nextel.com operated by the U.S. Department of Defense but is available for general use around the world. GPS Antenna An antenna de

Page 21

Appendix A: Glossary RFM-4000-5015 Rev1 107 Kbps Kilobits per second. Generally represented at 1000 bits per second. Laptops Portable computers, su

Page 22 - Modem Specifications

iR1200 Modem 108 nextel.com Packet of Data A bundle or block of data, organized in a specific way for transmission. Parallel Port A low speed port,

Page 23

Appendix A: Glossary RFM-4000-5015 Rev1 109 RAM Random Access Memory is the working memory of the computer where you can enter information and call

Page 24 - 14 nextel.com

iR1200 Modem 2 nextel.com

Page 25 - Getting Started

iR1200 Modem 110 nextel.com will be delivered in the same order in which they were sent. IP acts as a postal system, allowing you to address a packa

Page 26 - COMPUTER

Index RFM-4000-5015 Rev1 111 Index A AC Power Adapter · 3 B Bits · 29 C Circuit data · 8 COM1 · 29 Coverage · 5 CTS · 15 Customer Care · 5, 6 D Dat

Page 27 - Communication Indicators

iR1200 Modem 112 nextel.com IMEI · 6 Installation Guide · 3 L LED indicators · 15 M mobile IP · 32 Mobile IP · 2, 4, 27, 32, 33, 51, 52, 81 P Pacema

Page 28 - 18 nextel.com

FCC Compliance RFM-4002-5015 Rev 3 3 FCC Compliance DECLARATION OF CONFORMITYPer FCC CFR 47 2.989Responsible party name: eLutions, Inc.Address: 590

Page 29

iR1200 Modem 4 nextel.com

Page 30 - 20 nextel.com

Required Components RFM-4002-5015 Rev 3 5 Required Components The following table lists components that have been approved for use with the iR1200

Page 31 - Packet Data Applet

iR1200 Modem 6 nextel.com Online Documentation The iR1200 modem is shipped with the following product documentation. Additional copies of these d

Page 32 - Before You Begin

Introduction RFM-4002-5015 Rev 3 7 Introduction Welcome to Nextel Thank you for purchasing the Nextel iR1200 modem. This modem works on the iDEN

Page 33

iR1200 Modem 8 nextel.com Nextel Customer Care For customer care issues including technical support contact Nextel Customer Care at 1-800-639

Page 34 - 24 nextel.com

Overview RFM-4002-5015 Rev 3 9 Overview This chapter provides general details about the iR1200 modem. This chapter includes: General Overview Page

Page 36 - 26 nextel.com

iR1200 Modem 10 nextel.com Modem Operating Modes The iR1200 provides the following data connection modes: • Packet Data: A wireless modem connec

Page 37

Overview RFM-4002-5015 Rev 3 11 Figure 2. Rear Panel of iR1200 Rugged Modem iR1200 GPS-Enabled Modem The following diagram displays components on

Page 38 - 28 nextel.com

iR1200 Modem 12 nextel.com Modem Specifications Transmission Modes Circuit-Switched, Packet Data & Hayes AT Commands Rugged metal enclosure E

Page 39

Overview RFM-4002-5015 Rev 3 13 Vibration per TIA/EIA 603 par 3.3.4 Shock per MIL-STD-810E, method 516.4, procedure I Dust/Water Resistance Dust pe

Page 40

iR1200 Modem 14 nextel.com

Page 41

Getting Started RFM-4002-5015 Rev 3 15 Getting Started This chapter describes how to connect your modem to a computer or mobile device in preparati

Page 42 - 32 nextel.com

iR1200 Modem 16 nextel.com iR1200IGNITIONPOWERIGNITIONBYPASSPLUG120VACPOWERSUPPLYMODEMANTENNAGPS ANTENNA(OPTIONAL) COMPUTERRS-232GPS DATARS-232MO

Page 43

Getting Started RFM-4002-5015 Rev 3 17 5 Plug the AC power cord into the 2-prong polarized power jack located on the rear panel of the modem. Plu

Page 44 - 34 nextel.com

iR1200 Modem 18 nextel.com Signal Color Indication CTS Green (Off) Clear To Send from modem is asserted (not asserted). DTR Green (Off) Data

Page 45 - Verify Dial-Up Networking

Getting Started RFM-4002-5015 Rev 3 19 The following tables describe the STATUS indicators for the Packet Data and Circuit Switched Data operating

Page 46

Table of Contents Table of Contents Table of Figures...

Page 47

iR1200 Modem 20 nextel.com

Page 48 - System Administrator

Installing iDEN Packet Data Applet RFM-4002-5015 Rev 3 21 Installing iDEN Packet Data Applet In this chapter, you will learn how to install the iD

Page 49

iR1200 Modem 22 nextel.com NOTE: Please check the Nextel.com website for the latest hardware and installation requirements. Before You Begin Wind

Page 50 - 40 nextel.com

Installing iDEN Packet Data Applet RFM-4002-5015 Rev 3 23 The following table describes steps to download and install the iDEN data packet applet.

Page 51 - Manual Modem Configuration

iR1200 Modem 24 nextel.com computer. IMPORTANT: When you have finished downloading the program, you MUST connect the data cable to your modem an

Page 52 - 42 nextel.com

Installing iDEN Packet Data Applet RFM-4002-5015 Rev 3 25 16 Click OK to the message stating that you “must maximize the ‘Communication Settings’

Page 53

iR1200 Modem 26 nextel.com to connect to the modem. 19 The Packet Data Configuration window opens. Select No, I would like to configure my modem

Page 54 - 44 nextel.com

Installing iDEN Packet Data Applet RFM-4002-5015 Rev 3 27 2 From the Nextel Online page, find and select Wireless Web AccessPacketstreamGold.

Page 55

iR1200 Modem 28 nextel.com 13 The Choose Destination Location window opens. Click Next to accept the default destination folder, C:\Program File

Page 56 - 46 nextel.com

Installing iDEN Packet Data Applet RFM-4002-5015 Rev 3 29 24 The Remove Access Service window opens. Click Add. 25 The RAS Device window opens. V

Page 57

iR1200 Modem Circuit Switched Data ...19 Installing iDEN Packet Data

Page 58 - 48 nextel.com

iR1200 Modem 30 nextel.com 33 Select the following value on the Communication Settings window: • Click the Auto Detect to have the software au

Page 59

Installing iDEN Packet Data Applet RFM-4002-5015 Rev 3 31 process. 36 The Setup Complete window opens. Click Finish. Windows 2000 NOTE: Administra

Page 60 - 50 nextel.com

iR1200 Modem 32 nextel.com status window opens while the files are copying. 9 The Installshield Wizard screen appears during the setup process.

Page 61

Installing iDEN Packet Data Applet RFM-4002-5015 Rev 3 33 that your modem is connected and click Next. 21 The Digital Signature Not Found window o

Page 62 - 52 nextel.com

iR1200 Modem 34 nextel.com appropriate COM Port (typically COM1) • Multiple Baudrate should be unchecked • Baud Rate: 19200 (bps) The program w

Page 63 - Modem Profiles and Settings

Setting Up Windows Components RFM-4002-5015 Rev 3 35 Setting Up Windows Components In this chapter, you will learn how to set up Windows components

Page 64 - HyperTerminal Setup

iR1200 Modem 36 nextel.com Windows NT 1 From your desktop, double-click the My Computer icon to open the My Computer window. 2 Double-click the

Page 65

Setting Up Windows Components RFM-4002-5015 Rev 3 37 Windows 95/98/ME 1 From your desktop, double-click the My Computer icon to open the My Comput

Page 66 - 56 nextel.com

iR1200 Modem 38 nextel.com Windows NT/2000 In most cases the TCP/IP protocol was installed automatically. However, for Windows NT and 2000, TCP/I

Page 67 - Configuring With AT Commands

Setting Up Windows Components RFM-4002-5015 Rev 3 39 Installing the Dial-Up Adapter The following table describes the steps for installing the Dial

Page 68

Table of Contents Modem Configuration – Windows NT...44 Install the Modem...

Page 69

iR1200 Modem 40 nextel.com the connection wizard. Click Next. 3 Select I want to set up my Internet connection manually as above, then click on

Page 70

Manual Modem Configuration RFM-4002-5015 Rev 3 41 Manual Modem Configuration In this chapter, you will learn how to manually add a modem, configure

Page 71

iR1200 Modem 42 nextel.com from a list box. Click Next. 6 The Install New Modem/Modem Selection window opens. Under Manufacturer, select Standar

Page 72

Manual Modem Configuration RFM-4002-5015 Rev 3 43 • Use Flow Control and • Hardware (RTS/CTS) • If the Duplex option is present, select Full. 5

Page 73 - GPS Default Parameters

iR1200 Modem 44 nextel.com procedure creates the iR1200 Modem icon in the Dial-Up Networking window. 6 In the Dial-Up Networking window, right c

Page 74 - 64 nextel.com

Manual Modem Configuration RFM-4002-5015 Rev 3 45 2 The Modems Properties window opens. Under the General tab click Add. 3 The Install New Modem

Page 75 - AT Commands

iR1200 Modem 46 nextel.com occur and Windows NT will not recognize the Standard 19200 bps modem. 12 The Add RAS Device window opens. Make sure t

Page 76 - Network Status Commands

Manual Modem Configuration RFM-4002-5015 Rev 3 47 5 Click OK to close the Advanced Connection Settings window. 6 Click OK (or Close) to close the

Page 77 - Other Useful AT Commands

iR1200 Modem 48 nextel.com Edit entry and modem properties from the drop-down list. 9 The Edit Phonebook Entry window displays. Click the Server

Page 78

Manual Modem Configuration RFM-4002-5015 Rev 3 49 5 The Modem Detection window opens. Under Manufacturer, select (Standard Modem Types). Under Mod

Page 79

iR1200 Modem Saving AT Settings...62 GPS Default Parameters...

Page 80

iR1200 Modem 50 nextel.com 7 The Setting up your Internet connection window opens. Select I connect through a phone line and a modem and click N

Page 81

Manual Modem Configuration RFM-4002-5015 Rev 3 51 • Always use the following – should remain unchecked Under DNS server address: • My ISP automat

Page 82

iR1200 Modem 52 nextel.com 5 The iR1200 Modem window opens. Select the General tab. In the Phone number box, erase the temporary phone number pr

Page 83

Modem Profiles and Settings RFM-4002-5015 Rev 3 53 Modem Profiles and Settings In this chapter, you will learn how to use AT commands to setup para

Page 84

iR1200 Modem 54 nextel.com HyperTerminal Setup A HyperTerminal session must be setup for you to enter AT commands. The following table outlines s

Page 85

Modem Profiles and Settings RFM-4002-5015 Rev 3 55 6 Select the appropriate communication port (typically COM1) from the “Connect Using:” drop-do

Page 86

iR1200 Modem 56 nextel.com • Parity: None • Stop Bits: 1 • Flow Control: Hardware 9 Click OK when all the parameters have been selected. 10

Page 87

Modem Profiles and Settings RFM-4002-5015 Rev 3 57 Configuring With AT Commands Modem Initialization The iR1200 modem’s factory default image 2 is

Page 88

iR1200 Modem 58 nextel.com Configuration Command Syntax AT&F Expected Return Code(s) OK Activate DTR Monitoring The DCE does not monitor th

Page 89

Modem Profiles and Settings RFM-4002-5015 Rev 3 59 0,0,0 (Insert appropriate IP address where X appears.) Expected Return Code(s) OK ! IMPORTANT

Page 90

Table of Contents Local Flow Control (PCCA)...75 Local Data Rate ...

Page 91

iR1200 Modem 60 nextel.com Mobile IP Activation The modem makes use of mobile IP to manage a truly mobile computer. You may use a Mobile IP stack

Page 92

Modem Profiles and Settings RFM-4002-5015 Rev 3 61 AT Command MIP Authentication Key Command Syntax AT+WV301=”AAAXXX” (Make sure that the Authent

Page 93

iR1200 Modem 62 nextel.com (Insert appropriate prefix length where X appears.) Expected Return Code(s) OK Header Compression This command enable

Page 94

Modem Profiles and Settings RFM-4002-5015 Rev 3 63 IMPORTANT: These settings are stored on the modem’s Random Access Memory (RAM) and are lost when

Page 95

iR1200 Modem 64 nextel.com

Page 96 - 86 nextel.com

AT Commands RFM-4002-5015 Rev 3 65 AT Commands This chapter describes common AT commands that can be applied to the iR1200 modem. This chapter incl

Page 97 - S-Registers

iR1200 Modem 66 nextel.com User Image Profile Commands Command Usage Action ATz ATz0, ATz1, or ATz2 Sets the specified image as the active ima

Page 98 - Supported S-Registers

AT Commands RFM-4002-5015 Rev 3 67 AT+WS53? AT+WS53? Checks Signal Quality AT+WS50? AT+WS50? Check Signal Strength AT+WPSTATE AT+WPSTATE Chec

Page 99

iR1200 Modem 68 nextel.com Values: 1 = Enabled command mode character echo. Dial This command instructs the DCE to originate a call. When the DCE

Page 100 - 90 nextel.com

AT Commands RFM-4002-5015 Rev 3 69 Hang-up This command instructs the modem to terminate the active call. Command H Action ATh Query Range Re

Page 101 - Troubleshooting

iR1200 Modem Troubleshooting...91 Common Problems...

Page 102 - 92 nextel.com

iR1200 Modem 70 nextel.com Query Range Pulse Dialing This command selects pulse dialing. It is provided for compatibility purposes. Command

Page 103 - Error Messages

AT Commands RFM-4002-5015 Rev 3 71 Action ATt Query Range Verbose Result Codes This command sets your preference for the result code format. I

Page 104 - Diagnostic Commands

iR1200 Modem 72 nextel.com appropriate, but does not return the NO DIALTONE result code. 4 = The modem may return either the BUSY or NO DIALTONE

Page 105 - RFM-4002-5015 Rev 3

AT Commands RFM-4002-5015 Rev 3 73 Range Parameter Values: 0 = DCD always on 1 = The modem turns on the DCD to indicate the presence of a connect

Page 106 - 96 nextel.com

iR1200 Modem 74 nextel.com Action AT&f <setting> Query AT&v Range Local Flow Control (Traditional) This parameter selects the t

Page 107

AT Commands RFM-4002-5015 Rev 3 75 Query Range Local Character Framing This parameter determines the local serial port asynchronous data framin

Page 108 - 98 nextel.com

iR1200 Modem 76 nextel.com DCE_by_DTE Parameter Values: 0 = No flow control was set by DTE. 1 = XON/XOFF; do not pass XON/XOFF characters to the

Page 109 - Safety Notice

AT Commands RFM-4002-5015 Rev 3 77 38400 = Transmission speed in bits per second. 57600 = Transmission speed in bits per second. 115200 = Transmiss

Page 110 - Other Medical Devices

iR1200 Modem 78 nextel.com Command +WCPN Action AT+wcpn=<newPIN>, <oldPIN> Query Range AT+wcpn=? Parameter Values: A PIN is stor

Page 111 - Copyright and Trademark

AT Commands RFM-4002-5015 Rev 3 79 Query AT+wv312? Range AT+wv312=? Parameter Values: 68-1500 = MTU Value Range 1006 = Default Value Select Mobil

Page 112 - 102 nextel.com

Table of Contents IMPORTANT! Please Read Safety Notice on Page 99 before using the iR1200 Modem. Last Updated RFM-4002-5015 Rev 3 November 2003

Page 113 - Appendix A: Glossary

iR1200 Modem 80 nextel.com Parameter Values: The authentication Key parameter is a text string of up to 32 characters. Unlike most text-string pa

Page 114

AT Commands RFM-4002-5015 Rev 3 81 NOTE: This parameter is applicable only when the Mobile Node Client in the DCE is activated. Command +WPNEI Act

Page 115 - RFM-4000-5015 Rev1

iR1200 Modem 82 nextel.com Command +WV308 Action AT+wv308<encryption>, <firm offer>, <key size> Query AT+wv308? Range AT+wv

Page 116

AT Commands RFM-4002-5015 Rev 3 83 WDS Stack This command changes the data mode of the modem between circuit-switched data and packet data. Command

Page 117

iR1200 Modem 84 nextel.com Action AT+ws198<time> Query AT+ws198? Range AT+ws198=? Parameter Values: 1-255 = Seconds 30 = Default value C

Page 118

AT Commands RFM-4002-5015 Rev 3 85 Parameter Values: 1-255 = Seconds 30 = Default value Comma Dial Modifier Timer This command allows the DTE to se

Page 119

iR1200 Modem 86 nextel.com

Page 120 - UTC Offset

S-Registers RFM-4002-5015 Rev 3 87 S-Registers In this chapter, you are will learn about S-registers and how to configure registers for your iR1200

Page 121

iR1200 Modem 88 nextel.com ! If you write to an S-register that is not programmable or if the value you assigned is invalid, the modem will still

Page 122

S-Registers RFM-4002-5015 Rev 3 89 Register # Function Valid value ranges from 0 (zero) to 255. 0 (zero) is the default value. 2 Escape (ESC) Cod

Comments to this Manuals

No comments